-- CERENT-OPTICAL-MONITOR-MIB.mib
--
-- Copyright (c) 2002 by Cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************


CERENT-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Integer32, 
    MODULE-IDENTITY, 
    OBJECT-TYPE                         FROM SNMPv2-SMI
    TEXTUAL-CONVENTION,
    TruthValue                          FROM SNMPv2-TC
    MODULE-COMPLIANCE,
    OBJECT-GROUP                        FROM SNMPv2-CONF
    ifIndex                             FROM IF-MIB
    cerentModules,
    cerentRequirements,
    cerentGeneric                       FROM CERENT-GLOBAL-REGISTRY
    CerentPeriod                        FROM CERENT-TC
;

cerentOpticalMonitorMIB MODULE-IDENTITY
    LAST-UPDATED   "0211110000Z" -- 2002/Nov/11
    ORGANIZATION   "Cisco Systems, Inc."
    CONTACT-INFO   "support@Cisco.com

                    Postal:
                    Cisco Systems
                    1450 N. McDowell Blvd.
                    Petaluma, CA 94954

                    Tel: +1-877-323-7368"
    DESCRIPTION
        "This MIB module defines objects to monitor optical
        characteristics and set corresponding thresholds, on the 
        optical interfaces in a network element.
        This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
        "
        REVISION   "0211110000Z" -- 2002/Nov/11
        DESCRIPTION
            "The initial revision of this MIB."
        ::={ cerentModules 70 }


-- Textual Conventions

OpticalParameterType ::= TEXTUAL-CONVENTION
    STATUS    current
    DESCRIPTION
        "This value indicates the optical parameter that is
        being monitored. Valid values are -

        power (1)          : Optical Power (AC + DC). 
        acPower (2)        : Optical AC Power.
        apdTemp (3)        : Avalanche Photo Detector Temperature.
        laserTemp (4)      : Laser Temperature.
        biasCurrent (5)    : Laser bias current.
        peltierCurrent (6) : Laser peltier current.
        xcvrVoltage (7)    : Transceiver voltage.
        voa (8)	           : Variable Optical Attenuation Failure & Degrade Th.
        gain (9)           : Optical amplifier gain Failure & Degrade Th.
	oscPower (10)	   : OSC Optical Power
	addPower (11)	   : Add Optical Power
        "
        SYNTAX    INTEGER {
                  power(1),
                  acPower(2),
                  apdTemp(3),
                  laserTemp(4),
                  biasCurrent(5),
                  peltierCurrent(6),
                  xcvrVoltage(7),
                  voa(8),
                  gain(9),
		  oscPower(10),
		  addPower(11)
              }


OpticalParameterValue ::= TEXTUAL-CONVENTION
    STATUS    current
    DESCRIPTION   
        "The value of the optical parameter that is being monitored.

        The range of values varies depending on the type of optical
        parameter being monitored, as identified by a corresponding
        object with syntax OpticalParameterType.

        when the optical parameter being monitored is 'power' or 
        'acpower', the supported range is from -1000 to 1000, in 
        1/10ths of dBm.
        Example: Actual power of -40 dbm is represented as -400.
        Actual power level of +30 dBm is represented as 300.

        When the optical parameter being monitored is 'laserTemp' or
        'apdTemp', the supported range is from -10000 to 30000, in
        1/100ths of degrees centigrade.
        Example: A value of 2355 represents a temperature reading of
        23.55 degrees C.

        When the optical parameter being monitored is 'biasCurrent',
        the supported range is from 0 to 1000, in 1/10ths of
        percentage (%).
        Example: A value of 500 represents a bias current threshold
        of 50.0 %.

        When the optical parameter being monitored is 'peltierCurrent',
        the supported range is from 0 to 10000, in milliamperes. 

        When the optical parameter being monitored is 'xcvrVoltage',
        the supported range is from 0 to 100000, in 1/10ths of
        millivolts.
        Example: A Value of 115 represents a transceiver voltage
        reading of 11.5 millivolts.

        The distinguished value of '-1000000' indicates that the object
        has not yet been initialized or does not apply.
        "
    SYNTAX    Integer32 ( -1000000..1000000 )
      

OpticalIfDirection ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "This value indicates the direction being monitored at
        the optical interface.
        "
    SYNTAX      INTEGER {
                    receive(1),
                    transmit(2),
                    notApplicable(3)
                }


-- MIB Object Definitions

cerentOpticalMonitorMIBObjects       OBJECT IDENTIFIER ::=
                                        {cerentGeneric 30 }

-- groups in this MIB module

cerentOpticalMonGroup                OBJECT IDENTIFIER ::= 
                                        {cerentOpticalMonitorMIBObjects 1 }

cerentOpticalPMGroup                 OBJECT IDENTIFIER ::=
                                        {cerentOpticalMonitorMIBObjects 2 }

-- cOpticalMonTable

cOpticalMonTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF COpticalMonEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table provides objects to monitor optical
        parameters in a network element. It also provides
        objects for setting high and low threshold levels, with
        configurable severities, on these monitored parameters."
    ::={ cerentOpticalMonGroup 1 }

cOpticalMonEntry OBJECT-TYPE 
    SYNTAX      COpticalMonEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the cOpticalMonTable provides objects to
        monitor an optical parameter and set threshold levels
        on that parameter, at an optical interface.

        Note that the set of monitored optical parameters may vary
        based on interface type and direction.

        Examples of interfaces that can have an entry in this table
        include optical transceivers optical amplifiers, 
        and optical attenuators."
    INDEX        { ifIndex, cOpticalMonDirection, 
                   cOpticalMonParameterType }
    ::={ cOpticalMonTable 1 }


COpticalMonEntry ::= SEQUENCE {
    cOpticalMonDirection                OpticalIfDirection,
    cOpticalMonParameterType            OpticalParameterType,
    cOpticalParameterValue              OpticalParameterValue,
    cOpticalParamHighAlarmThresh        OpticalParameterValue,
    cOpticalParamHighWarning15MinThresh OpticalParameterValue,
    cOpticalParamHighWarning1DayThresh  OpticalParameterValue,
    cOpticalParamLowAlarmThresh         OpticalParameterValue,
    cOpticalParamLowWarning15MinThresh  OpticalParameterValue,
    cOpticalParamLowWarning1DayThresh   OpticalParameterValue,
    cOpticalParamLowDegradeThresh       OpticalParameterValue,
    cOpticalParamHighDegradeThresh      OpticalParameterValue
}

cOpticalMonDirection OBJECT-TYPE
    SYNTAX      OpticalIfDirection 
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the cOpticalMonTable
        and indicates the direction monitored for the
        optical interface, in this entry."
    ::={ cOpticalMonEntry 1 }


cOpticalMonParameterType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the cOpticalMonTable
        and specifies the optical parameter that is being monitored,
        in this entry."
    ::={ cOpticalMonEntry 2 }

cOpticalParameterValue OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the value measured for the particular
        optical parameter specified by the cOpticalMonParameterType
        object."
    ::={ cOpticalMonEntry 3 }

cOpticalParamHighAlarmThresh OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a high alarm threshold on the 
        optical parameter being monitored.

        If the measured value of the parameter,is greater than the 
        value configured in this object, an alarm will be raised.

        When the cOpticalMonParameterType object is set to 'power'
        for the receive direction at a transceiver, this object
        specifies the receiver saturation level."
    ::={ cOpticalMonEntry 4 }


cOpticalParamHighWarning15MinThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a high warning 15 minute threshold  
        on the optical parameter being monitored.

        If the measured value of the parameter,is greater than the 
        value configured in this object, an alarm may be raised."
    ::={ cOpticalMonEntry 5 }

cOpticalParamHighWarning1DayThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a high warning 1 day threshold on  
        the optical parameter being monitored.

        If the measured value of the parameter,is greater than the 
        value configured in this object, an alarm may be raised."
    ::={ cOpticalMonEntry 6 }
    
cOpticalParamLowAlarmThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a low alarm threshold on the 
        optical parameter being monitored.

        If the measured value of the parameter,goes lower than the 
        value configured in this object, an alarm will be raised.

        When the cOpticalMonParameterType object is set to 'power'
        for the receive direction and when the interface supports
        alarms based on loss of light, this object specifies the
        optical power threshold for declaring loss of light. Also,
        when optical amplifiers are present in the network, in the
        receive direction, this value may need to be configured,
        since the noise floor may be higher than the minimum
        sensitivity of the receiver."
    ::={ cOpticalMonEntry 7 }

cOpticalParamLowWarning15MinThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a low warning 15 minute threshold 
        on the optical parameter being monitored.

        If the measured value of the parameter,goes lower than the 
        value configured in this object, an alarm will be raised."
    ::={ cOpticalMonEntry 8 }

cOpticalParamLowWarning1DayThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a low warning 1 day threshold  
        on the optical parameter being monitored.

        If the measured value of the parameter,goes lower than the 
        value configured in this object, an alarm will be raised."
    ::={ cOpticalMonEntry 9 }

cOpticalParamLowDegradeThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a low degrade threshold  
        on the optical parameter being monitored.

        If the measured value of the parameter,goes lower than the 
        value configured in this object, a degrade alarm will be raised."
    ::={ cOpticalMonEntry 10 }

cOpticalParamHighDegradeThresh OBJECT-TYPE 
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to set a high degrade threshold  
        on the optical parameter being monitored.

        If the measured value of the parameter,goes lower than the 
        value configured in this object, a degrade alarm will be raised."
    ::={ cOpticalMonEntry 11 }


-- cOpticalPMCurrent Table

cOpticalPMCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF COpticalPMCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table stores performance monitoring data for the
        various optical parameters, collected over the current
        interval."
    ::={ cerentOpticalPMGroup 1 }

cOpticalPMCurrentEntry OBJECT-TYPE
    SYNTAX      COpticalPMCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the cOpticalPMCurrentTable. It contains
        performance monitoring data for an optical parameter,
        collected over the current interval.

        Note that the set of monitored optical parameters may vary
        based on interface type and direction.

        Examples of interfaces that can have an entry in this table
        include optical transceivers, optical amplifiers, and optical
        attenuators."
    INDEX      { ifIndex,
                 cOpticalPMCurrentDirection,
                 cOpticalPMCurrentParamType,
                 cOpticalPMCurrentPeriod}
    ::={ cOpticalPMCurrentTable 1 }

COpticalPMCurrentEntry ::= SEQUENCE {
    cOpticalPMCurrentDirection         OpticalIfDirection,
    cOpticalPMCurrentParamType         OpticalParameterType,
    cOpticalPMCurrentPeriod            CerentPeriod,
    cOpticalPMCurrentMaxParam          OpticalParameterValue,
    cOpticalPMCurrentMinParam          OpticalParameterValue,
    cOpticalPMCurrentMeanParam         OpticalParameterValue
}


cOpticalPMCurrentDirection OBJECT-TYPE
    SYNTAX      OpticalIfDirection
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the cOpticalPMCurrentTable 
        and indicates the direction monitored
        for the optical interface, in this entry."
    ::={ cOpticalPMCurrentEntry 1 }

cOpticalPMCurrentParamType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the
        cOpticalPMCurrentTable and specifies the optical parameter 
        that is being monitored, in this entry."
    ::={ cOpticalPMCurrentEntry 2 }
    
cOpticalPMCurrentPeriod OBJECT-TYPE
    SYNTAX      CerentPeriod
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the
        cOpticalPMCurrentTable and indicates whether the
        optical parameter values given in this entry, are collected
        over a period of 15 minutes or 24 hours."
    ::={ cOpticalPMCurrentEntry 3 }

cOpticalPMCurrentMaxParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the maximum value measured for the optical
        parameter, in the current 15 minute or 24 hour interval." 
    ::={ cOpticalPMCurrentEntry 4 }

cOpticalPMCurrentMinParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the minimum value measured for the optical
        parameter, in the current 15 minute or 24 hour interval." 
    ::={ cOpticalPMCurrentEntry 5 }

cOpticalPMCurrentMeanParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the average value of the measured optical
        parameter, in the current 15 minute or 24 hour interval." 
    ::={ cOpticalPMCurrentEntry 6 }

-- cOpticalPMInterval Table

cOpticalPMIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF COpticalPMIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table stores performance monitoring data for the
        various optical parameters, collected over current and 
        previous intervals.

        This table can have entries for up to 96 complete 15 minute  
        intervals."
    ::={ cerentOpticalPMGroup 2 }

cOpticalPMIntervalEntry OBJECT-TYPE
    SYNTAX      COpticalPMIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the cOpticalPMIntervalTable. It contains
        performance monitoring data for an optical parameter,
        collected over current and previous intervals.

        Note that the set of monitored optical parameters may vary
        based on interface type and direction.

        Examples of interfaces that can have an entry in this table
        include optical transceivers, optical amplifiers, and optical
        attenuators."
    INDEX      { ifIndex,
                 cOpticalPMIntervalDirection,
                 cOpticalPMIntervalParamType,
                 cOpticalPMIntervalPeriod,
                 cOpticalPMIntervalNumber}
    ::={ cOpticalPMIntervalTable 1 }

COpticalPMIntervalEntry ::= SEQUENCE {
    cOpticalPMIntervalDirection         OpticalIfDirection,
    cOpticalPMIntervalParamType         OpticalParameterType,
    cOpticalPMIntervalPeriod            CerentPeriod,
    cOpticalPMIntervalNumber            Integer32,
    cOpticalPMIntervalMaxParam          OpticalParameterValue,
    cOpticalPMIntervalMinParam          OpticalParameterValue,
    cOpticalPMIntervalMeanParam         OpticalParameterValue,
    cOpticalPMIntervalValidData         TruthValue  
}


cOpticalPMIntervalDirection OBJECT-TYPE
    SYNTAX      OpticalIfDirection
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the cOpticalPMIntervalTable 
        and indicates the direction monitored
        for the optical interface, in this entry."
    ::={ cOpticalPMIntervalEntry 1 }

cOpticalPMIntervalParamType OBJECT-TYPE
    SYNTAX      OpticalParameterType
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the
        cOpticalPMIntervalTable and specifies the optical parameter 
        that is being monitored, in this entry."
    ::={ cOpticalPMIntervalEntry 2 }
    
cOpticalPMIntervalPeriod OBJECT-TYPE
    SYNTAX      CerentPeriod
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is an index into the
        cOpticalPMIntervalTable and indicates whether the
        optical parameter values given in this entry, are collected
        over a period of 15 minutes or 24 hours."
    ::={ cOpticalPMIntervalEntry 3 }

cOpticalPMIntervalNumber OBJECT-TYPE
    SYNTAX      Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
         "This object is an index into the cOpticalPMIntervalTable. 
         It is a number between 1 and 96, which identifies the
         interval for which the set of optical parameter values is
         available. The interval identified by 1 is the most recent
         15 minute or 24 hour interval, and the interval
         identified by N is the interval immediately preceding the one
         identified by N-1."
    ::={ cOpticalPMIntervalEntry 4 }

cOpticalPMIntervalMaxParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the maximum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::={ cOpticalPMIntervalEntry 5 }

cOpticalPMIntervalMinParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the minimum value measured for the optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::={ cOpticalPMIntervalEntry 6 }

cOpticalPMIntervalMeanParam OBJECT-TYPE
    SYNTAX      OpticalParameterValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object gives the average value of the measured optical
        parameter, in a particular 15 minute or 24 hour interval." 
    ::={ cOpticalPMIntervalEntry 7 }

cOpticalPMIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "This variable indicates if the data for this
         interval is valid."
   ::= { cOpticalPMIntervalEntry 8 }


-- MIB Conformance Statements

cerentOpticalMonitorMIBConformance  OBJECT IDENTIFIER ::= 
                                { cerentRequirements 20 }

cerentOpticalMonitorMIBCompliances  OBJECT IDENTIFIER ::= 
                                { cerentOpticalMonitorMIBConformance 1 }

cerentOpticalMonitorMIBGroups       OBJECT IDENTIFIER ::= 
                                { cerentOpticalMonitorMIBConformance 2 }


cerentOpticalMonitorMIBCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION 
        "The compliance statement for network elements that
        monitor optical characteristics and set thresholds on the 
        optical interfaces in a network element."
    MODULE      -- this module
        MANDATORY-GROUPS { cerentOpticalMIBMonGroup }

    GROUP cerentOpticalMIBThresholdGroup
    DESCRIPTION
        "This group is required for network elements that support
        thresholds on optical parameters."

    GROUP cerentOpticalMIBPMGroup
    DESCRIPTION        
        "This group is required for network elements that
        support collection of optical performance monitoring
        data for 15 minute or 24 hour intervals."

    OBJECT     cOpticalParamHighAlarmThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT     cOpticalParamHighWarning15MinThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT     cOpticalParamHighWarning1DayThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT     cOpticalParamLowAlarmThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT     cOpticalParamLowWarning15MinThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT     cOpticalParamLowWarning1DayThresh
    MIN-ACCESS read-only
    DESCRIPTION
        "Write access is not required."

    ::={ cerentOpticalMonitorMIBCompliances 1 }

-- Units of Conformance

cerentOpticalMIBMonGroup OBJECT-GROUP
    OBJECTS {
        cOpticalParameterValue
    }
    STATUS        current
    DESCRIPTION
        "A mandatory object that provides monitoring of optical
        characteristics."
    ::={ cerentOpticalMonitorMIBGroups 1 }

cerentOpticalMIBThresholdGroup OBJECT-GROUP
    OBJECTS {
        cOpticalParamHighAlarmThresh,
        cOpticalParamHighWarning15MinThresh,
        cOpticalParamHighWarning1DayThresh,
        cOpticalParamLowAlarmThresh,
        cOpticalParamLowWarning15MinThresh,
        cOpticalParamLowWarning1DayThresh
    }
    STATUS        current
    DESCRIPTION
        "A collection of objects that support thresholds on optical
        parameters and provide status information when the thresholds
        are exceeded or cleared."
    ::={ cerentOpticalMonitorMIBGroups 2 } 

cerentOpticalMIBPMGroup OBJECT-GROUP
    OBJECTS {
        cOpticalPMCurrentMaxParam,
        cOpticalPMCurrentMinParam,
        cOpticalPMCurrentMeanParam,
        cOpticalPMIntervalMaxParam,
        cOpticalPMIntervalMinParam,
        cOpticalPMIntervalMeanParam,
        cOpticalPMIntervalValidData  
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects that provide optical performance
        monitoring data for 15 minute and 24 hour intervals."
    ::={ cerentOpticalMonitorMIBGroups 3 }

cerentOpticalDwdmNetworkMIBThresholdGroup OBJECT-GROUP
    OBJECTS {
        cOpticalParamHighAlarmThresh,
        cOpticalParamHighWarning15MinThresh,
        cOpticalParamHighWarning1DayThresh,
        cOpticalParamLowAlarmThresh,
        cOpticalParamLowWarning15MinThresh,
        cOpticalParamLowWarning1DayThresh,
	cOpticalParamLowDegradeThresh,
	cOpticalParamHighDegradeThresh
    }
    STATUS        current
    DESCRIPTION
        "A collection of objects that support thresholds on optical
        DWDM Network parameters and provide status information when 
	the thresholds are exceeded or cleared."
    ::={ cerentOpticalMonitorMIBGroups 4 } 

END 