-- Copyright (c) 2004-2014 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description:
-- Reference:
-- Version: V1.7
-- History:
-- V1.0 created by liujingya.
--     Initial version of the MIB
-- V1.1 2008-1-29 Adjusted the structure of some tables and the value of
--     some objects by liujingya.
-- V1.2 2008-5-19 Added hh3cEOCComUniAdminStatus, hh3cEOCComCnuSoftwareVersion,
--     modified description of hh3cEOCComUniUpLineRate and
--     hh3cEOCComUniDownLineRate by liujingya.
-- V1.3 2008-7-30 updated by xujun
--     add hh3cEOCComCnuRateDropThr, hh3cEOCComCnuTxRate, hh3cEOCComCnuRxRate,
--     hh3cEOCComCnuTxRateDrop, hh3cEOCComCnuRxRateDrop, hh3cEOCCnuTxRateDropTrap,
--     hh3cEOCCnuTxRateDropRecoverTrap, hh3cEOCCnuRxRateDropTrap and
--     hh3cEOCCnuRxRateDropRecoverTrap by xujun
-- V1.4 2009-2-13 Added hh3cEOCCnuFWDownLoadErrTrap,
--     hh3cEOCCnuFWDownLoadErrReTrap, hh3cEOCCnuDeviceTypeErrTrap,
--     hh3cEOCCnuDeviceTypeErrReTrap, hh3cEOCCnuAutoUpdateErrTrap,
--     hh3cEOCCnuAutoUpdateSuccTrap and
--     modified MAX-ACCESS of hh3cEOCComCnuDeviceType by liujingya.
-- V1.5 2010-1-7 Added hh3cEocComCnuTypeIdx, hh3cEOCComCnuDescripton,
--     hh3cEOCComCltMaxAllowToAccess, hh3cEocComCnuNumber by xujun
-- V1.6 2011-12-28 updated by gaoguangping
--     Added hh3cEOCLoopbackDetectTrap, hh3cEOCLoopbackRecoverTrap;
--     Modified hh3cEOCComCnuLinkState.
-- V1.7 2013-08-20 Added hh3cEOCComCnuTempIndex by xujun
-- =================================================================
HH3C-EOC-COMMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
        hh3cCommon
    FROM HH3C-OID-MIB
        ifIndex, ifDescr
    FROM IF-MIB
        Integer32, Unsigned32, TimeTicks, OBJECT-TYPE, MODULE-IDENTITY,
        NOTIFICATION-TYPE, Gauge32
    FROM SNMPv2-SMI
        IANAifType
    FROM IANAifType-MIB
        MacAddress, RowStatus, DisplayString, TruthValue
    FROM SNMPv2-TC
        hh3cHPEOCDownLoadCNUFWResult
    FROM HH3C-HPEOC-MIB;


hh3cEOCCommon MODULE-IDENTITY
    LAST-UPDATED "200709111008Z"
    ORGANIZATION
        "New H3C Tech. Co., Ltd."
    CONTACT-INFO
        "SMB EOC Team New H3C Technologies Co., Ltd.
        Shang-Di Information Industry Base,
        Hai-Dian District Beijing P.R. China
        http://www.h3c.com
        Zip:310053."
    DESCRIPTION
        "
        The objects in this MIB module are used to manage and
        display common configuration between Ethernet Passive
        Optical Network (EOC) port which are based on the Ethernet
        in the First Mile (EFM) Passive Optical Network(PON) as
        defined in IEEE Draft P802.3ah/D3.0 clause 60, 64, 65..
        and Ethernet Over Cable (EOC) which is based on HomePlug
        AV Specification.
        "
    ::= { hh3cCommon 83 }

--
-- hh3cEOCCommonSysMan
--
hh3cEOCCommonSysMan OBJECT IDENTIFIER ::= { hh3cEOCCommon 1 }

hh3cEOCCommonSysScalarObjects OBJECT IDENTIFIER ::= { hh3cEOCCommonSysMan 1 }

hh3cEOCCommonSysVersion OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        Eoc version.  If the object length is
        zero, it means the version is unknown.
        The length is up to 1024.
        "
    ::= { hh3cEOCCommonSysScalarObjects 1 }

hh3cEOCCommonUpLinkMacAddress OBJECT-TYPE
    SYNTAX     MacAddress
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        EOC CLT's uplink device's mac address.
        "
    ::= { hh3cEOCCommonSysScalarObjects 2 }


--
-- hh3cEOCCommonCltMan
--
hh3cEOCCommonCltMan OBJECT IDENTIFIER ::= { hh3cEOCCommon 2 }

--
-- hh3cEOCCommonCltManTable
--
hh3cEOCCommonCltManTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCCommonCltManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table defines the primary parameters of the
        CLT configuration.
        "
    ::= { hh3cEOCCommonCltMan 1 }

hh3cEOCCommonCltManEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCCommonCltManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the table hh3cEOCCommonCltManTable.
        "
    INDEX
        {
            ifIndex
        }
    ::= { hh3cEOCCommonCltManTable 1 }

Hh3cEOCCommonCltManEntry ::= SEQUENCE
    {
        hh3cEOCCommonCltAutoAuthorize    TruthValue,
        hh3cEOCCommonCltMaxAllowToAccess Integer32
    }

hh3cEOCCommonCltAutoAuthorize OBJECT-TYPE
    SYNTAX     TruthValue
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        This value determines whether software performs
        self-authorization for each Cable Network Unit(CNU)
        registering to the network.  Setting it to false
        means for every CNU registering, software requires
        external authorization, and until it's done the
        CNU is not authenticated.  True value means software
        authorizes each CNU registering to the network
        automatically.
        "
    DEFVAL
        {
            false
        }
    ::= { hh3cEOCCommonCltManEntry 1 }

hh3cEOCCommonCltMaxAllowToAccess OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "
         This value determines how many CNU can be bound
         in this CLT. If the number of CNU is more than this
         value , then the rest of CNU should not be allow to
         access.
         "
    DEFVAL
        {
            253
        }
    ::= { hh3cEOCCommonCltManEntry 2 }

--
-- hh3cEOCComCnuMan
--

hh3cEOCComCnuMan OBJECT IDENTIFIER ::= { hh3cEOCCommon 3 }

hh3cEOCComCnuScalarObjects OBJECT IDENTIFIER ::= { hh3cEOCComCnuMan 1 }

hh3cEOCComCnuMaxDownBWMinVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The lower limit of total-bandwidth which is confined to
        hh3cEOCComCnuMaxDownBW."
    ::= { hh3cEOCComCnuScalarObjects 1 }

hh3cEOCComCnuMaxDownBWMaxVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The upper limit of total-bandwidth which is confined to
        hh3cEOCComCnuMaxDownBW."
    ::= { hh3cEOCComCnuScalarObjects 2 }

hh3cEOCComCnuSlaHighPriBWMinVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The lower limit of high priority bandwidth which is confined to
        hh3cEOCComCnuSlaHighPriBW."
    ::= { hh3cEOCComCnuScalarObjects 3 }

hh3cEOCComCnuSlaHighPriBWMaxVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The upper limit of high priority bandwidth which is confined to
        hh3cEOCComCnuSlaHighPriBW."
    ::= { hh3cEOCComCnuScalarObjects 4 }

hh3cEOCComCnuMaxUpBWMinVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The lower limit of total-bandwidth which is confined to
        hh3cEOCComCnuMaxUpBW."
    ::= { hh3cEOCComCnuScalarObjects 5 }

hh3cEOCComCnuMaxUpBWMaxVal OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The upper limit of total-bandwidth which is confined to
        hh3cEOCComCnuMaxUpBW."
    ::= { hh3cEOCComCnuScalarObjects 6 }

hh3cEOCComCnuAttenThrA OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The value of cnu's average attenuation good level thresholds.
        "
    ::= { hh3cEOCComCnuScalarObjects 7 }

hh3cEOCComCnuAttenThrB OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The value of cnu's average attenuation normal level thresholds.
        "
    ::= { hh3cEOCComCnuScalarObjects 8 }

hh3cEOCComCnuRateDropThr OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The value of cnu's Tx/Rx rate drop thresholds.
        "
    ::= { hh3cEOCComCnuScalarObjects 9 }

--
-- hh3cEOCComCnuSysManTable
--

hh3cEOCComCnuSysManTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuSysManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table implements the management of CNUs(Coax Network Unit).
        "
    ::= { hh3cEOCComCnuMan 2 }

hh3cEOCComCnuSysManEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuSysManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the table hh3cEOCComCnuSysManTable.
        "
    INDEX
        {
            ifIndex
        }
    ::= { hh3cEOCComCnuSysManTable 1 }

Hh3cEOCComCnuSysManEntry ::= SEQUENCE
    {
        hh3cEOCComCnuCableIfindex    Integer32,
        hh3cEOCComCnuDeviceType      DisplayString,
        hh3cEOCComCnuDeviceAlias     DisplayString,
        hh3cEOCComCnuDescr           DisplayString,
        hh3cEOCComCnuUpTime          TimeTicks,
        hh3cEOCComCnuVLANType        INTEGER,
        hh3cEOCComCnuPvid            Integer32,
        hh3cEOCComCnuVlanTag         INTEGER,
        hh3cEOCComCnuReset           INTEGER,
        hh3cEOCComCnuDeregister      INTEGER,
        hh3cEOCComCnuSave            INTEGER,
        hh3cEOCComCnuAccess          INTEGER
    }

hh3cEOCComCnuCableIfindex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The index of cable port which uniquely identifies the cable
        port of one device.
        "
    ::= { hh3cEOCComCnuSysManEntry 1 }

hh3cEOCComCnuDeviceType OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The type of the EOC CNU(Coax Network Unit).
        "
    ::= { hh3cEOCComCnuSysManEntry 2 }

hh3cEOCComCnuDeviceAlias OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "
        EOC CNU's alias which display as the device's name,
        it's recommended to set it uniquely and understandably.
        "
    ::= { hh3cEOCComCnuSysManEntry 3 }

hh3cEOCComCnuDescr OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        User's description, including user's address,
        name, telephone number and so on.
        "
    ::= { hh3cEOCComCnuSysManEntry 4 }

hh3cEOCComCnuUpTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The time since the CNU last registered to the network.
        "
    ::= { hh3cEOCComCnuSysManEntry 5 }

hh3cEOCComCnuVLANType OBJECT-TYPE
    SYNTAX     INTEGER
        {
            vLANTrunk(1),
            access(2),
            hybrid(3),
            fabric(4)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "port vlan types.
        hybrid (3) port can carry multiple VLANs.
        If fabric function is supported, fabric(4) means the port is
        a fabric port."
    ::= { hh3cEOCComCnuSysManEntry 6 }

hh3cEOCComCnuPvid OBJECT-TYPE
    SYNTAX     Integer32 (1..4094)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The PVID, the VLAN ID assigned to untagged frames or
        Priority-Tagged frames received on cable interface.
        "
    REFERENCE
        "
        IEEE 802.1Q/D11 Section 12.10.1.1
        "
    DEFVAL
        {
            1
        }
    ::= { hh3cEOCComCnuSysManEntry 7 }

hh3cEOCComCnuVlanTag OBJECT-TYPE
    SYNTAX     INTEGER
        {
            tagged(1),
            untagged(2)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        VLAN is set tagged or untagged on cable interface.
        "
    ::= { hh3cEOCComCnuSysManEntry 8 }

hh3cEOCComCnuReset OBJECT-TYPE
    SYNTAX     INTEGER
        {
            running(1),
            reset(2)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        This variable is used to reset the CNU device. The
        interface may be unavailable while the reset occurs and
        data may be lost. During reading operation it returns
        the state of the CNU device. running(1) indicates and
        operates normal operation, reset(2) indicates and
        operates reset mode. Writing can be done all the time.
        "
    ::= { hh3cEOCComCnuSysManEntry 9 }

hh3cEOCComCnuDeregister OBJECT-TYPE
    SYNTAX     INTEGER
        {
            deregister(1)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        deregister CNU.
        "
    ::= { hh3cEOCComCnuSysManEntry 10 }

hh3cEOCComCnuSave OBJECT-TYPE
    SYNTAX     INTEGER
        {
            save(1),
            running(2)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        Save the UNI and CNU related configurations to
        the CNU.
        "
    ::= { hh3cEOCComCnuSysManEntry 11 }

hh3cEOCComCnuAccess OBJECT-TYPE
    SYNTAX     INTEGER
        {
            access(1),
            notaccess(2)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        Control whether the user can access to the network.
        "
    ::= { hh3cEOCComCnuSysManEntry 12 }

--
-- hh3cEOCComCnuMacTable
--

hh3cEOCComCnuMacTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuMacEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table implements the management of CNUs.
        "
    ::= { hh3cEOCComCnuMan 3 }

hh3cEOCComCnuMacEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuMacEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the table hh3cEOCComCnuMacTable.
        "
    INDEX
        {
            ifIndex
        }
    ::= { hh3cEOCComCnuMacTable 1 }

Hh3cEOCComCnuMacEntry ::= SEQUENCE
    {
        hh3cEOCComCnuMacAddress    MacAddress,
        hh3cEOCComCnuRowStatus     RowStatus,
        hh3cEOCComCnuTempIndex     Integer32
    }

hh3cEOCComCnuMacAddress OBJECT-TYPE
    SYNTAX     MacAddress
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "
        EOC CNU's MAC address.
        "
    ::= { hh3cEOCComCnuMacEntry 1 }

hh3cEOCComCnuRowStatus OBJECT-TYPE
    SYNTAX     RowStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "
        Operation status.
        "
    ::= { hh3cEOCComCnuMacEntry 2 }
    
hh3cEOCComCnuTempIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        EOC CNU's model index from hh3cHPEOCTemplateIndex,
        If configure 0, the CNU select no model.
        "
    ::= { hh3cEOCComCnuMacEntry 3 }
    
--
-- hh3cEOCComCnuInfoTable
--

hh3cEOCComCnuInfoTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuInfoEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        Primary status of the specified CNU.
        There will be one row in this table for each
        information in the system.
        "
    ::= { hh3cEOCComCnuMan 4 }

hh3cEOCComCnuInfoEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuInfoEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the hh3cEOCComCnuInfoTable.
        "
    INDEX
        {
            ifIndex
        }
    ::= { hh3cEOCComCnuInfoTable 1 }

Hh3cEOCComCnuInfoEntry ::= SEQUENCE
    {
        hh3cEOCComCnuHardwareVersion    DisplayString,
        hh3cEOCComCnuPCBVersion         OCTET STRING,
        hh3cEOCComCnuLinkState          INTEGER,
        hh3cEOCComCnuAttenuation        Integer32,
        hh3cEOCComCnuSoftwareVersion    DisplayString,
        hh3cEOCComCnuTxRate             Integer32,
        hh3cEOCComCnuRxRate             Integer32,
        hh3cEOCComCnuTxRateDrop         Integer32,
        hh3cEOCComCnuRxRateDrop         Integer32
    }

hh3cEOCComCnuHardwareVersion OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        EOC CNU's hardware version.  If the object length is
        zero, it means the version is unknown.
        "
    ::= { hh3cEOCComCnuInfoEntry 1 }

hh3cEOCComCnuPCBVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        EOC CNU's PCB version.
        "
    ::= { hh3cEOCComCnuInfoEntry 2 }

hh3cEOCComCnuLinkState OBJECT-TYPE
    SYNTAX     INTEGER
        {
            physicaldown(1),
            linkdown(2),
            linkup(3),
            loopback(4)
        }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cable port's link state.  The physicaldown(1) state indicates
        that the CNU is not powered on.  The linkdown(2) state indicates
        that the CNU is powered on, but registers fail.  The linkup(3)
        state indicates that the CNU is powered on, and registers
        successful.  The loopback(4) state indecates that the CNU is
        powered on and registers successful, but loopback has detected.
        "
    ::= { hh3cEOCComCnuInfoEntry 3 }

hh3cEOCComCnuAttenuation OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cnu's average attenuation.
        "
    ::= { hh3cEOCComCnuInfoEntry 4 }

hh3cEOCComCnuSoftwareVersion OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        EOC CNU's software version.  If the object length is
        zero, it means the version is unknown.
        "
    ::= { hh3cEOCComCnuInfoEntry 5 }

hh3cEOCComCnuTxRate OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cnu's capability of tx speed in unit of 1Mbps.
        "
    ::= { hh3cEOCComCnuInfoEntry 6 }

hh3cEOCComCnuRxRate OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cnu's capability of rx speed in unit of 1Mbps.
        "
    ::= { hh3cEOCComCnuInfoEntry 7 }

hh3cEOCComCnuTxRateDrop OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cnu's capability droping of tx
        speed from it's history max value in unit of %.
        "
    ::= { hh3cEOCComCnuInfoEntry 8 }

hh3cEOCComCnuRxRateDrop OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The cnu's capability droping of rx
        speed from it's history max value in unit of %.
        "
    ::= { hh3cEOCComCnuInfoEntry 9 }

--
-- hh3cEOCComCnuBandWidthTable
--

hh3cEOCComCnuBandWidthTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuBandWidthEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        Set bandwidth parameters.
        "
    ::= { hh3cEOCComCnuMan 5 }

hh3cEOCComCnuBandWidthEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuBandWidthEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of table hh3cEOCComCnuBandWidthTable.
        It is a pre-configuration.
        "
    INDEX
        {
            ifIndex
        }
    ::= { hh3cEOCComCnuBandWidthTable 1 }

Hh3cEOCComCnuBandWidthEntry ::= SEQUENCE
    {
        hh3cEOCComCnuMaxDownBW       Integer32,
        hh3cEOCComCnuSlaHighPriBW    Integer32,
        hh3cEOCComCnuMaxUpBW         Integer32
    }

hh3cEOCComCnuMaxDownBW OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        Maximum bandwidth allowed for the CNU,
        measured in Kbit/s.
        "
    ::= { hh3cEOCComCnuBandWidthEntry 1 }

hh3cEOCComCnuSlaHighPriBW OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        High priority bandwidth - measured in Kbit/s.
        The value of this object should be the multiple of
        the value of hh3cEOCComCnuMaxUpBW.
        The high priority bandwidth should not be larger than the maximum
        bandwidth.
        "
    ::= { hh3cEOCComCnuBandWidthEntry 2 }

hh3cEOCComCnuMaxUpBW OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        Total bandwidth - measured in Kbit/s.
        The value of this object should be the multiple of
        the value of hh3cEOCComCnuSlaHighPriBW.
        The total bandwidth should be larger than the high priority bandwidth.
        "
    ::= { hh3cEOCComCnuBandWidthEntry 3 }




--
-- hh3cEOCComUniMan
--

hh3cEOCComUniMan OBJECT IDENTIFIER ::= { hh3cEOCCommon 4 }

hh3cEOCComUniManTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComUniManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table defines several user network interface(UNI) system
        parameters.
        "
    ::= { hh3cEOCComUniMan 1 }

hh3cEOCComUniManEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComUniManEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of hh3cEOCComUniManTable.
        "
    INDEX
        {
            ifIndex,
            hh3cEOCUniIndex
        }
    ::= { hh3cEOCComUniManTable 1 }

Hh3cEOCComUniManEntry ::= SEQUENCE
    {
        hh3cEOCUniIndex               Unsigned32,
        hh3cEOCComUniDescr            DisplayString,
        hh3cEOCComUniStatus           INTEGER,
        hh3cEOCComUniSpeed            INTEGER,
        hh3cEOCComUniDuplex           INTEGER,
        hh3cEOCComUniCurrentSpeed     Gauge32,
        hh3cEOCComUniCurrentDuplex    INTEGER,
        hh3cEOCComUniMdi              INTEGER,
        hh3cEOCComUniFlowControl      TruthValue,
        hh3cEOCComUniCountReset       INTEGER,
        hh3cEOCComUniAlias            DisplayString,
        hh3cEOCComUniType             IANAifType,
        hh3cEOCComUniVLANType         INTEGER,
        hh3cEOCComUniPvid             Integer32,
        hh3cEOCComUniVlanTag          INTEGER,
        hh3cEOCComUniPriority         Integer32,
        hh3cEOCComUniUpLineRate       Unsigned32,
        hh3cEOCComUniDownLineRate     Unsigned32,
        hh3cEOCComUniAdminStatus      INTEGER
    }

hh3cEOCUniIndex OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The index value which uniquely identifies the FE(Fast Ethernet)
        interface of the CNU.
        "
    ::= { hh3cEOCComUniManEntry 1 }

hh3cEOCComUniDescr OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        A textual string containing information about the interface.  This
        string should include the name of the manufacturer, the product
        name and the version of the interface hardware and software.
        "
    ::= { hh3cEOCComUniManEntry 2 }

hh3cEOCComUniStatus OBJECT-TYPE
    SYNTAX     INTEGER
        {
            up(1),
            down(2),
            testing(3)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The desired state of the user network interface. When a managed
        system initializes, all user network interfaces start with down
        state. The testing state indicates that no operational packets
        can be passed. As a result of either explicit management action or
        per configuration information retained by the managed system,
        hh3cEOCComUniStatus is then changed to either the up or
        testing states (or remains in the down state).
        "
    ::= { hh3cEOCComUniManEntry 3 }

hh3cEOCComUniSpeed OBJECT-TYPE
    SYNTAX     INTEGER
        {
            auto(1),
            s10M(10),
            s100M(100)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        User network interface speed.
        "
    ::= { hh3cEOCComUniManEntry 4 }

hh3cEOCComUniDuplex OBJECT-TYPE
    SYNTAX     INTEGER
        {
            full(1),
            half(2),
            auto(3)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        User network interface mode.
        "
    ::= { hh3cEOCComUniManEntry 5 }

hh3cEOCComUniCurrentSpeed OBJECT-TYPE
    SYNTAX     Gauge32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        An estimate of the interface's current bandwidth in
        bits per second.  For interfaces which do not vary in
        bandwidth or for those where no accurate estimation
        can be made, this object should contain the nominal
        bandwidth.  If the bandwidth of the interface is
        greater than the maximum value reportable by this
        object then this object should report its maximum
        value (4,294,967,295).  For a sub-layer which
        has no concept of bandwidth, this object should be
        zero.
        "
    ::= { hh3cEOCComUniManEntry 6 }

hh3cEOCComUniCurrentDuplex OBJECT-TYPE
    SYNTAX     INTEGER
        {
            full(1),
            half(2),
            unknown(3)
        }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The current mode of operation of the MAC
        entity.  'unknown' indicates that the current
        duplex mode could not be determined.

        Management control of the duplex mode is
        accomplished through the MAU MIB.  When
        an interface does not support autonegotiation,
        or when autonegotiation is not enabled, the
        duplex mode is controlled using
        ifMauDefaultType.  When autonegotiation is
        supported and enabled, duplex mode is controlled
        using ifMauAutoNegAdvertisedBits.  In either
        case, the currently operating duplex mode is
        reflected both in this object and in ifMauType.

        Note that this object provides redundant
        information with ifMauType.  Normally, redundant
        objects are discouraged.  However, in this
        instance, it allows a management application to
        determine the duplex status of an interface
        without having to know every possible value of
        ifMauType.  This was felt to be sufficiently
        valuable to justify the redundancy.
        "
    REFERENCE
        "
        [IEEE 802.3 Std.], 30.3.1.1.32, aDuplexStatus.
        "
    ::= { hh3cEOCComUniManEntry 7 }

hh3cEOCComUniMdi OBJECT-TYPE
    SYNTAX     INTEGER
        {
            mdi-ii(1),
            mdi-x(2),
            mdi-auto(3)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "Type of the line connected to UNI interface:
        mdi-ii(straight-through cable),
        mdi-x (crossover cable),
        mdi-auto (auto-sensing)."
    DEFVAL
        {
            mdi-auto
        }
    ::= { hh3cEOCComUniManEntry 8 }

hh3cEOCComUniFlowControl OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Flow control status.
        true(1)  - Flow control status enable.
        false(2) - Flow control status disable."
    DEFVAL
        {
            false
        }
    ::= { hh3cEOCComUniManEntry 9 }

hh3cEOCComUniCountReset OBJECT-TYPE
    SYNTAX      INTEGER
        {
            reset(1)
        }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Reset the counter which is about packets of the interface,
        then the counter will change to zero.  There is no sense in
        reading this object."
    ::= { hh3cEOCComUniManEntry 10 }

hh3cEOCComUniAlias OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        This object is an 'alias' name for the interface as
        specified by a network manager, and provides a non-
        volatile 'handle' for the interface.

        On the first instantiation of an interface, the value
        of hh3cEOCComUniAlias associated with that interface is the
        zero-length string.  As and when a value is written
        into an instance of hh3cEOCComUniAlias through a network
        management set operation, then the agent must retain
        the supplied value in the hh3cEOCComUniAlias instance associated
        with the same interface for as long as that interface
        remains instantiated, including across all re-
        initializations/reboots of the network management
        system, including those which result in a change of
        the interface's ifIndex and hh3cEOCUniIndex value.

        An example of the value which a network manager might
        store in this object for a WAN interface is the
        (Telco's) circuit number/identifier of the interface.

        Some agents may support write-access only for
        interfaces having particular values of hh3cEOCComUniType.  An
        agent which supports write access to this object is
        required to keep the value in non-volatile storage,
        but it may limit the length of new values depending on
        how much storage is already occupied by the current
        values for other interfaces.
        "
    ::= { hh3cEOCComUniManEntry 11 }

hh3cEOCComUniType OBJECT-TYPE
    SYNTAX     IANAifType
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The type of interface.  Additional values for hh3cEOCComUniType
        are assigned by the Internet Assigned Numbers
        Authority(IANA), through updating the syntax of the
        IANAifType textual convention.
        "
    ::= { hh3cEOCComUniManEntry 12 }

hh3cEOCComUniVLANType OBJECT-TYPE
    SYNTAX     INTEGER
        {
            vLANTrunk(1),
            access(2),
            hybrid(3),
            fabric(4)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "port vlan types.
        hybrid (3) port can carry multiple VLANs.
        If fabric function is supported, fabric(4) means the port is
        a fabric port."
    ::= { hh3cEOCComUniManEntry 13 }

hh3cEOCComUniPvid OBJECT-TYPE
    SYNTAX     Integer32 (1..4094)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The PVID, the VLAN ID assigned to untagged frames or
        Priority-Tagged frames received on this port.
        "
    REFERENCE
        "
        IEEE 802.1Q/D11 Section 12.10.1.1
        "
    DEFVAL
        {
            1
        }
    ::= { hh3cEOCComUniManEntry 14 }

hh3cEOCComUniVlanTag OBJECT-TYPE
    SYNTAX     INTEGER
        {
            tagged(1),
            untagged(2)
        }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        VLAN is set tagged or untagged.
        "
    ::= { hh3cEOCComUniManEntry 15 }

hh3cEOCComUniPriority OBJECT-TYPE
    SYNTAX     Integer32 (0..7)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The default ingress User Priority for this port.  This
        only has effect on media, such as Ethernet, that do not
        support native User Priority.
        "
    ::= { hh3cEOCComUniManEntry 16 }

hh3cEOCComUniUpLineRate OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The max speed upload in units of 1,000 bits per second
        on this interface.  The value should between 0 and 100Mbps.
        If the value is 0, it means that the upload speed is only
        restricted by the physical line.
        "
    ::= { hh3cEOCComUniManEntry 17 }

hh3cEOCComUniDownLineRate OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "
        The max speed download in units of 1,000 bits per second
        on this interface.  The value should between 0 and 100Mbps.
        If the value is 0, it means that the download speed is only
        restricted by the physical line.
        "
    ::= { hh3cEOCComUniManEntry 18 }

hh3cEOCComUniAdminStatus OBJECT-TYPE
    SYNTAX      INTEGER
        {
            up(1),
            down(2)
        }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "
        Control if open or close the UNI.  If choose up(1), means the UNI is
        opened and packets can pass it.  If choose down(2), means the UNI is
        closed and all packets will be discard.
        "
    ::= { hh3cEOCComUniManEntry 19 }

--
-- hh3cEOCComUniCountTable
--
hh3cEOCComUniCountTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hh3cEOCComUniCountEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A list of interface counter about frames entries."
    ::= { hh3cEOCComUniMan 2 }

hh3cEOCComUniCountEntry OBJECT-TYPE
    SYNTAX      Hh3cEOCComUniCountEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing management information applicable
        to a particular interface."
    INDEX
        {
            ifIndex,
            hh3cEOCUniIndex
        }
    ::= { hh3cEOCComUniCountTable 1 }

Hh3cEOCComUniCountEntry ::= SEQUENCE
    {
        hh3cEOCUniInPkts                     Unsigned32,
        hh3cEOCUniInUPkts                    Unsigned32,
        hh3cEOCUniInBPkts                    Unsigned32,
        hh3cEOCUniInMPkts                    Unsigned32,
        hh3cEOCUniInPausePkts                Unsigned32,
        hh3cEOCUniInTotalErrors              Unsigned32,
        hh3cEOCUniInCRCErrs                  Unsigned32,
        hh3cEOCUniInUndersizePkts            Unsigned32,
        hh3cEOCUniInOversizePkts             Unsigned32,
        hh3cEOCUniInErrorbyOther             Unsigned32,
        hh3cEOCUniInOctets                   Unsigned32,
        hh3cEOCUniOutPkts                    Unsigned32,
        hh3cEOCUniOutUPkts                   Unsigned32,
        hh3cEOCUniOutBPkts                   Unsigned32,
        hh3cEOCUniOutMPkts                   Unsigned32,
        hh3cEOCUniOutPausePkts               Unsigned32,
        hh3cEOCUniOutTotalErrors             Unsigned32,
        hh3cEOCUniOutCollisions              Unsigned32,
        hh3cEOCUniOutDelayExceedDsds         Unsigned32,
        hh3cEOCUniOutErrorbyOther            Unsigned32,
        hh3cEOCUniOutDroppedFrames           Unsigned32,
        hh3cEOCUniOutOctets                  Unsigned32
    }

hh3cEOCUniInPkts OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad packets,
        broadcast packets, and multicast packets) received."
    ::= { hh3cEOCComUniCountEntry 1 }

hh3cEOCUniInUPkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets received that are
        directed to the unicast address.  Note that this
        does not include multicast and broadcast packets."
    ::= { hh3cEOCComUniCountEntry 2 }

hh3cEOCUniInBPkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets received that are
        directed to the broadcast address.  Note that this
        does not include multicast packets."
    ::= { hh3cEOCComUniCountEntry 3 }

hh3cEOCUniInMPkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets received that are
        directed to a multicast address.  Note that this number
        does not include packets directed to the broadcast address."
    ::= { hh3cEOCComUniCountEntry 4 }

hh3cEOCUniInPausePkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "A count of MAC Control packets received on this
        interface by the pause(flow control) operation.
        This counter does not increment when the
        interface is in a half-duplex mode.
        Discontinuities in the value of this counter can
        occur at re-initialization of the management
        system."
    ::= { hh3cEOCComUniCountEntry 5 }

hh3cEOCUniInTotalErrors  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "Total count of the error packets received on this interface."
    ::= { hh3cEOCComUniCountEntry 6 }

hh3cEOCUniInCRCErrs  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that
        had a length (excluding framing bits, but
        including FCS octets) of between 64 and 1518
        octets, inclusive, but had either a bad
        Frame Check Sequence (FCS) with an integral
        number of octets (FCS Error) or a bad FCS with
        a non-integral number of octets (Alignment Error)."
    ::= { hh3cEOCComUniCountEntry 7 }

hh3cEOCUniInUndersizePkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that are
        less than 64 octets long (excluding framing bits,
        but including FCS octets) and are otherwise well formed."
    ::= { hh3cEOCComUniCountEntry 8 }

hh3cEOCUniInOversizePkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that are
        longer than 1518 octets (excluding framing bits,
        but including FCS octets) and are otherwise well formed."
    ::= { hh3cEOCComUniCountEntry 9 }

hh3cEOCUniInErrorbyOther   OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of other error packets received on this interface."
    ::= { hh3cEOCComUniCountEntry 10 }

hh3cEOCUniInOctets   OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of octets received on this interface."
    ::= { hh3cEOCComUniCountEntry 11 }

hh3cEOCUniOutPkts OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad packets,
        broadcast packets, and multicast packets) sent."
    ::= { hh3cEOCComUniCountEntry 12 }

hh3cEOCUniOutUPkts OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets sent that are
        directed to the unicast address.  Note that this
        does not include multicast and broadcast packets."
    ::= { hh3cEOCComUniCountEntry 13 }

hh3cEOCUniOutBPkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets sent that are
        directed to the broadcast address.  Note that this
        does not include multicast packets."
    ::= { hh3cEOCComUniCountEntry 14 }

hh3cEOCUniOutMPkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets sent that are
        directed to a multicast address.  Note that this number
        does not include packets directed to the broadcast address."
    ::= { hh3cEOCComUniCountEntry 15 }

hh3cEOCUniOutPausePkts  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of MAC control packets sent on this
        interface by the pause operation.  This counter does
        not increment when the interface is in a half-duplex mode.
        Discontinuities in the value of this counter can
        occur at re-initialization of the management system."
    ::= { hh3cEOCComUniCountEntry 16 }

hh3cEOCUniOutTotalErrors  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of error packets sent on this interface."
    ::= { hh3cEOCComUniCountEntry 17 }

hh3cEOCUniOutCollisions  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The best estimate of the total number of collisions
        on this Ethernet segment.
        The value returned will depend on the location of the
        RMON probe.  Section 8.2.1.3 (10BASE-5) and section
        10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
        station must detect a collision, in the receive mode, if
        three or more stations are transmitting simultaneously.  A
        repeater port must detect a collision when two or more
        stations are transmitting simultaneously.  Thus a probe
        placed on a repeater port could record more collisions
        than a probe connected to a station on the same segment
        could.  Probe location plays a much smaller role when considering
        10BASE-T.  14.2.1.4 (10BASE-T) of IEEE standard 802.3
        defines a collision as the simultaneous presence of signals
        on the DO and RD circuits (transmitting and receiving
        at the same time).  A 10BASE-T station can only detect
        collisions when it is transmitting.  Thus probes placed on
        a station and a repeater, should report the same number of
        collisions.  Note also that an RMON probe inside a repeater should
        ideally report collisions between the repeater and one or
        more other hosts (transmit collisions as defined by IEEE
        802.3k) plus receiver collisions observed on any coax
        segments to which the repeater is connected."
    ::= { hh3cEOCComUniCountEntry 18 }

hh3cEOCUniOutDelayExceedDsds  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS  current
    DESCRIPTION
        "The number of packets discarded by this port due
        to excessive transit delay through the bridge.  It
        is incremented by both transparent and source route bridges."
    ::= { hh3cEOCComUniCountEntry 19 }

hh3cEOCUniOutErrorbyOther  OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of other error packets sent on this interface.
        Other error packets means the error packets out of collision packets
        and excessive delayed packets."
    ::= { hh3cEOCComUniCountEntry 20 }

hh3cEOCUniOutDroppedFrames OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of frames dropped because of buffer failure."
    ::= { hh3cEOCComUniCountEntry 21 }

hh3cEOCUniOutOctets   OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of octets transmitted out of the interface."
    ::= { hh3cEOCComUniCountEntry 22 }

--
-- hh3cEOCCommon NOTIFICATION
--

hh3cEOCCommonTrap OBJECT IDENTIFIER ::= { hh3cEOCCommon 5 }

hh3cEOCTrapPrefix OBJECT IDENTIFIER ::= {hh3cEOCCommonTrap 0}

hh3cEOCCnuRegExcessTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRegExcessTrap notification is sent when the
        number of registered CNUs exceeds the limit.
        "
    ::= { hh3cEOCTrapPrefix 1 }

hh3cEOCCnuRegExcessRecoverTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRegExcessRecoverTrap notification is sent when
        hh3cEOCCnuRegExcessTrap is detected and then recoverd.
        "
    ::= { hh3cEOCTrapPrefix 2 }

hh3cEOCCnuRegSuccTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRegSuccTrap notification is sent when a
        CNU registers successful.
        "
    ::= { hh3cEOCTrapPrefix 3 }

hh3cEOCCnuOffLineTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuOffLineTrap notification is sent when a
        CNU offline.
        "
    ::= { hh3cEOCTrapPrefix 4 }

hh3cEOCCnuLinkupTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuLinkupTrap notification is sent when a
        CNU linkup.
        "
    ::= { hh3cEOCTrapPrefix 5 }

hh3cEOCOamDisconnectTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCOamDisconnectionTrap notification is sent when
        LLID's OAM link is disconnected.
        "
    ::= { hh3cEOCTrapPrefix 6 }

hh3cEOCOamDisconnectRecoverTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCOamDisconnectionRecoverTrap notification is sent when
        LLID's OAM link is disconnected and then connected.
        "
    ::= { hh3cEOCTrapPrefix 7 }


hh3cEOCBandwidthNotEnoughTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        Bandwidth is not enough, cnu can not bind now.
        "
    ::= { hh3cEOCTrapPrefix 8 }

hh3cEOCCnuAttenuationTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuAttenuation
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cHPEOCCnuAttenuationTrap notification is sent when a
        CNU's attenuation is changing.
        "
    ::= { hh3cEOCTrapPrefix 9 }

hh3cEOCCnuRegFailTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRegFailTrap notification is sent when a
        CNU registers fail.
        "
    ::= { hh3cEOCTrapPrefix 10 }

hh3cEOCCLTCablePortErrorTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCLTCablePortErrorTrap notification is sent when the
        hardware of cable port occurs error or CLT's vlan is configged
        error.
        "
    ::= { hh3cEOCTrapPrefix 11 }

hh3cEOCCLTCablePortErrReTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCLTCablePortErrReTrap notification is sent when cable port
        error and then recovered.
        "
    ::= { hh3cEOCTrapPrefix 12 }

hh3cEOCCnuTxRateDropTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuTxRateDrop
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuTxRateDropTrap notification is sent when cable port
        rate of TX capability drop exceeded threshold.
        "
    ::= { hh3cEOCTrapPrefix 13 }

hh3cEOCCnuTxRateDropRecoverTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuTxRateDrop
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuTxRateDropRecoverTrap notification is sent when cable port
        rate of TX capability recover from the recent rate-drop trap.
        "
    ::= { hh3cEOCTrapPrefix 14 }

hh3cEOCCnuRxRateDropTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuRxRateDrop
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRxRateDropTrap notification is sent when cable port
        rate of RX capability drop exceeded threshold.
        "
    ::= { hh3cEOCTrapPrefix 15 }

hh3cEOCCnuRxRateDropRecoverTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuRxRateDrop
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuRxRateDropRecoverTrap notification is sent when cable port
        rate of RX capability recover from the recent rate-drop trap.
        "
    ::= { hh3cEOCTrapPrefix 16 }

hh3cEOCCnuFWDownLoadErrTrap NOTIFICATION-TYPE
    OBJECTS
        {
            hh3cHPEOCDownLoadCNUFWResult
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuFWDownLoadErrTrap notification is sent when CLT can't
        download CNU firmware from the server successfully.
        "
    ::= { hh3cEOCTrapPrefix 17 }

hh3cEOCCnuFWDownLoadErrReTrap NOTIFICATION-TYPE
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuFWDownLoadErrReTrap notification is sent when CLT recover
        from the download CNU firmware error.
        "
    ::= { hh3cEOCTrapPrefix 18 }

hh3cEOCCnuDeviceTypeErrTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress,
            hh3cEOCComCnuDeviceType
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuDeviceTypeErrTrap notification is sent when the online CNU
        doesn't match the type which user defined earlier.
        "
    ::= { hh3cEOCTrapPrefix 19 }

hh3cEOCCnuDeviceTypeErrReTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuDeviceTypeErrReTrap notification is sent when the online CNU
        doesn't match the type which user defined earlier and then recover.
        "
    ::= { hh3cEOCTrapPrefix 20 }

hh3cEOCCnuAutoUpdateErrTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuAutoUpdateErrTrap notification is sent when the online CNU
        doesn't auto update successfully.
        "
    ::= { hh3cEOCTrapPrefix 21 }

hh3cEOCCnuAutoUpdateSuccTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCCnuAutoUpdateSuccTrap notification is sent when the online CNU
        auto update successfully.
        "
    ::= { hh3cEOCTrapPrefix 22 }

hh3cEOCLoopbackDetectTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCLoopbackDetectTrap notification is sent when the loopback between
        the ethernet ports of CNU or CLT is found.
        "
    ::= { hh3cEOCTrapPrefix 23 }

hh3cEOCLoopbackRecoverTrap NOTIFICATION-TYPE
    OBJECTS
        {
            ifIndex,
            ifDescr,
            hh3cEOCComCnuMacAddress
        }
    STATUS current
    DESCRIPTION
        "
        A hh3cEOCLoopbackRecoverTrap notification is sent when the loopback between
        the ethernet ports of CNU or CLT is recover.
        "
    ::= { hh3cEOCTrapPrefix 24 }

--
-- hh3cEOCComOnLineCnuMan
--

hh3cEOCComOnLineCnuMan OBJECT IDENTIFIER ::= { hh3cEOCCommon 6 }
--
-- hh3cEOCComCnuTypeTable
--
hh3cEOCComCnuTypeTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuTypeEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table defines the description of cnu typ.
        "
    ::= { hh3cEOCComOnLineCnuMan 1 }

hh3cEOCComCnuTypeEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuTypeEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the table hh3cEOCComCnuTypeTable.
        "
    INDEX
        {
            hh3cEOCComCnuTypeIdx
        }
    ::= { hh3cEOCComCnuTypeTable 1 }

Hh3cEOCComCnuTypeEntry ::= SEQUENCE
    {
        hh3cEOCComCnuTypeIdx    Unsigned32,
        hh3cEOCComCnuDescripton DisplayString
    }

hh3cEOCComCnuTypeIdx OBJECT-TYPE
    SYNTAX     Unsigned32
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        A unique value for each cnu types.  Its value
        ranges between 1 and the value of cny typess.
        "
    ::= { hh3cEOCComCnuTypeEntry 1 }

hh3cEOCComCnuDescripton OBJECT-TYPE
    SYNTAX     DisplayString
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The description for unique cnu types.
        "
    ::= { hh3cEOCComCnuTypeEntry 2 }

--
-- hh3cEOCComCnuNumTable
--

hh3cEOCComCnuNumTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF Hh3cEOCComCnuNumEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        This table defines the number of cnu registered in variable types
        of the CLT .
        "
    ::= { hh3cEOCComOnLineCnuMan 2 }

hh3cEOCComCnuNumEntry OBJECT-TYPE
    SYNTAX     Hh3cEOCComCnuNumEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "
        The entry of the table hh3cEOCComCnuNumTable.
        "
    INDEX
        {
            ifIndex,
            hh3cEOCComCnuTypeIdx
        }
    ::= { hh3cEOCComCnuNumTable 1 }

Hh3cEOCComCnuNumEntry ::= SEQUENCE
    {
        hh3cEOCComCnuNumber     Integer32
    }

hh3cEOCComCnuNumber OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "
        The number of special type of cnu that has been registerd in clt.
        "
    ::= { hh3cEOCComCnuNumEntry 1 }

END