HP-ICF-INST-MON DEFINITIONS ::= BEGIN

IMPORTS
    OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    TruthValue, DisplayString
        FROM SNMPv2-TC
    InterfaceIndexOrZero
        FROM IF-MIB
    hpSwitch
        FROM HP-ICF-OID;

hpicfInstMonMIB MODULE-IDENTITY
    LAST-UPDATED "200601230000Z"
    ORGANIZATION "Hewlett-Packard Company
                  ProCurve Networking Business"
    CONTACT-INFO "Hewlett-Packard Company
                  8000 Foothills Blvd.
                  Roseville, CA 95747"
    DESCRIPTION  "This MIB module contains HP proprietary
                  definitions for Instrumentation Monitor."

    REVISION     "200601230000Z"
    DESCRIPTION  "Initial revision."

    ::= { hpSwitch 35 }

-- **********************************************************************
-- The Instrumentation Monitor MIB Groups
-- **********************************************************************

hpicfInstMonObjects OBJECT IDENTIFIER
    ::= { hpicfInstMonMIB 1 }

hpicfInstMonConformance OBJECT IDENTIFIER
    ::= { hpicfInstMonMIB 2 }

hpicfInstMonGroups OBJECT IDENTIFIER
    ::= { hpicfInstMonConformance 1 }

hpicfInstMonCompliances OBJECT IDENTIFIER
    ::= { hpicfInstMonConformance 2 }

-- **********************************************************************
-- Start of MIB objects
-- **********************************************************************

hpicfInstMonLogEnable OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "The operational status of the Instrumentation Monitor
                 on this switch."
    DEFVAL      { false }
    ::= { hpicfInstMonObjects 1 }

hpicfInstMonTrapEnable OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "The operational status of the Monitor notifications
                 on this switch."
    DEFVAL      { true }
    ::= { hpicfInstMonObjects 2 }

-- Start of hpicfInstMonParameterTable **********************************

hpicfInstMonParameterTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF HpicfInstMonParameterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Configuration of monitored instrumentation parameters."
    ::= { hpicfInstMonObjects 3 }

hpicfInstMonParameterEntry OBJECT-TYPE
    SYNTAX      HpicfInstMonParameterEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the hpicfInstMonParameterTable."
    INDEX       { hpicfInstMonInterfaceIndex,
                  hpicfInstMonParameterIndex }
    ::= { hpicfInstMonParameterTable 1 }

HpicfInstMonParameterEntry ::= SEQUENCE {
    hpicfInstMonInterfaceIndex     InterfaceIndexOrZero,
    hpicfInstMonParameterIndex     INTEGER,
    hpicfInstMonParameterName      DisplayString,
    hpicfInstMonParameterThreshold Integer32 }

hpicfInstMonInterfaceIndex OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "0 for global parameters, port number for per-port
                 parameters."
    ::= { hpicfInstMonParameterEntry 1 }

hpicfInstMonParameterIndex OBJECT-TYPE
    SYNTAX      INTEGER( 1..'FFFF'h )
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "The index of the parameter."
    ::= { hpicfInstMonParameterEntry 2 }

hpicfInstMonParameterName OBJECT-TYPE
    SYNTAX      DisplayString( SIZE( 0..20 ) )
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The name of the parameter."
    ::= { hpicfInstMonParameterEntry 3 }

hpicfInstMonParameterThreshold OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "Generate notification if the limit is not 0 and
                 parameter value is beyond this limit."
    ::= { hpicfInstMonParameterEntry 4 }

-- End of hpicfInstMonParameterTable ************************************

hpicfInstMonNotificationText OBJECT-TYPE
    SYNTAX      DisplayString( SIZE( 0..255 ) )
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "This string is sent with hpicfInstMonNotification."
    ::= { hpicfInstMonObjects 4 }

hpicfInstMonNotification NOTIFICATION-TYPE
    OBJECTS     { hpicfInstMonNotificationText }
    STATUS      current
    DESCRIPTION "This notification is generated when the monitored
                 parameter is beyond the configured threshold value."
    ::= { hpicfInstMonObjects 5 }

-- **********************************************************************
-- Conformance Information
-- **********************************************************************

hpicfInstMonNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS { hpicfInstMonNotification }
    STATUS      current
    DESCRIPTION "This notification is generated by Monitor when
                 parameter is beyond its threshold limit."
    ::= { hpicfInstMonGroups 1 }

hpicfInstMonBaseGroup OBJECT-GROUP
    OBJECTS   { hpicfInstMonLogEnable,
                hpicfInstMonTrapEnable,
                hpicfInstMonInterfaceIndex,
                hpicfInstMonParameterIndex,
                hpicfInstMonParameterName,
                hpicfInstMonParameterThreshold }
    STATUS      current
    DESCRIPTION "A collection of objects to support basic Instrumentation
                 Monitor configuration on ProCurve switches."
    ::= { hpicfInstMonGroups 2 }

-- **********************************************************************
-- Compliance statements
-- **********************************************************************

hpicfInstMonBaseCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION "The compliance statement for ProCurve switches running
                 Instrumentation Monitor and implementing the
                 HP-ICF-INST-MON MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hpicfInstMonBaseGroup }
    ::= { hpicfInstMonCompliances 1 }

END