-- *  Moxa Fiber Check - Fiber Check PRIVATE MIB
-- *
-- *  Copyright (c) 2019 by Moxa Inc.
-- *  All rights reserved.
-- *****************************************************************

MOXA-FIBER-CHECK-MIB DEFINITIONS ::= BEGIN
    IMPORTS
        MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, Unsigned32
            FROM SNMPv2-SMI
        TEXTUAL-CONVENTION, RowStatus, DisplayString, TruthValue
            FROM SNMPv2-TC
        layer2Diagnosic
            FROM MOXA-SWITCHING-MIB;

    mxFiberCheck   MODULE-IDENTITY
        LAST-UPDATED "202202170000Z"
        ORGANIZATION "Moxa Inc."
        CONTACT-INFO
            "
            Postal: Moxa Inc.
            13F., No. 3, Sec. 4, New Taipei Blvd.
            Xinzhuang Dist., New Taipei City 242032, Taiwan, R.O.C.

            Tel: +866-2-89191230
            Web: http://www.moxa.com/
            "
        DESCRIPTION
            "The MIB module defines Moxa Fiber Check"

        REVISION    "202202170000Z"
        DESCRIPTION "update CONTACT-INFO"

        REVISION    "202108020000Z"
        DESCRIPTION    "Initial Revision"
        ::= { layer2Diagnosic 3 }

-- -------------------------------------------------------------
-- groups in the MOXA-FIBER-CHECK-MIB MIB
-- -------------------------------------------------------------

    fiberCheckNotification       OBJECT IDENTIFIER ::= { mxFiberCheck 0 }
    fiberCheckConfiguration      OBJECT IDENTIFIER ::= { mxFiberCheck 1 }
    fiberCheckStatus             OBJECT IDENTIFIER ::= { mxFiberCheck 2 }
    -- fiberCheckExtensions         OBJECT IDENTIFIER ::= { mxFiberCheck 3 }

-- -------------------------------------------------------------
-- configuration group
-- -------------------------------------------------------------

    fiberCheckConfigGeneral             OBJECT IDENTIFIER ::= {fiberCheckConfiguration 1}

-- -------------------------------------------------------------
-- fiberCheck general
-- -------------------------------------------------------------

fiberCheckConfigPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FiberCheckConfigPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The Fiber Check table of general config function."
        ::= { fiberCheckConfigGeneral 1 }

    fiberCheckConfigPortEntry OBJECT-TYPE
        SYNTAX FiberCheckConfigPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The Fiber Check table entry of general config function."
        INDEX { fiberCheckConfigPortIndex }
        ::= { fiberCheckConfigPortTable 1 }

    FiberCheckConfigPortEntry ::=
        SEQUENCE {
            fiberCheckConfigPortIndex
                INTEGER,
            fiberCheckConfigMode
                INTEGER,
            fiberCheckConfigTemperatureWarnC
                DisplayString,
            fiberCheckConfigTemperatureWarnF
                DisplayString,
            fiberCheckConfigTxPowerWarnHigh
                DisplayString,
            fiberCheckConfigTxPowerWarnLow
                DisplayString,
            fiberCheckConfigRxPowerWarnHigh
                DisplayString,
            fiberCheckConfigRxPowerWarnLow
                DisplayString,
            fiberCheckConfigResetToDefault
                TruthValue
        }

    fiberCheckConfigPortIndex OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The fiber index of config function."
         ::= { fiberCheckConfigPortEntry 1 }

    fiberCheckConfigMode OBJECT-TYPE
        SYNTAX INTEGER {
            auto(0),
            user-defined(1)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Users configure mode to define threshold by user."
        ::= { fiberCheckConfigPortEntry 2 }

    fiberCheckConfigTemperatureWarnC OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Users configure the high warning value of fiber temperature (Celsius) to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 3 }

    fiberCheckConfigTemperatureWarnF OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Users configure the high warning value of fiber temperature (Fahrenheit) to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 4 }

    fiberCheckConfigTxPowerWarnHigh OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Users configure the high warning value of fiber tx power to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 5 }

    fiberCheckConfigTxPowerWarnLow OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Users configure the low warning value of fiber tx power to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 6 }

    fiberCheckConfigRxPowerWarnHigh OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Users configure the high warning value of fiber rx power to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 7 }

    fiberCheckConfigRxPowerWarnLow OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Users configure the low warning value of fiber rx power to determine which value issue the fiber check warning."
        ::= { fiberCheckConfigPortEntry 8 }

    fiberCheckConfigResetToDefault OBJECT-TYPE
        SYNTAX    TruthValue
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Writing true(1) to this object forces the system to 
             reset this port's fiber check configuration to default.
             Any other operation on this object has no effect and it
             always returns false(2) when read."
        ::= { fiberCheckConfigPortEntry 9 }

-- -------------------------------------------------------------
-- Status group
-- -------------------------------------------------------------

    fiberCheckStatMonitor             OBJECT IDENTIFIER ::= {fiberCheckStatus 1}

-- -------------------------------------------------------------
-- Monitor
-- -------------------------------------------------------------

    fiberCheckStatPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF FiberCheckStatPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The fiber check table."
        ::= { fiberCheckStatMonitor 1 }

    fiberCheckStatPortEntry OBJECT-TYPE
        SYNTAX FiberCheckStatPortEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The fiber check table entry."
        INDEX { fiberCheckStatPortIndex }
        ::= { fiberCheckStatPortTable 1 }

    FiberCheckStatPortEntry ::=
        SEQUENCE {
            fiberCheckStatPortIndex
                INTEGER,
            fiberCheckStatModelName
                DisplayString,
            fiberCheckStatSN
                DisplayString,
            fiberCheckStatWaveLength
                INTEGER,
            fiberCheckStatTemperatureC
                DisplayString,
            fiberCheckStatTemperatureF
                DisplayString,
            fiberCheckStatVoltage
                DisplayString,
            fiberCheckStatTxPower
                DisplayString,
            fiberCheckStatRxPower
                DisplayString,
            fiberCheckStatTemperatureLimitC
                DisplayString,
            fiberCheckStatTemperatureLimitF
                DisplayString,
            fiberCheckStatTxPowerLimit
                DisplayString,
            fiberCheckStatRxPowerLimit
                DisplayString
        }

    fiberCheckStatPortIndex OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The port index fiber module."
        ::= { fiberCheckStatPortEntry 1 }

    fiberCheckStatModelName OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The model name of fiber module."
        ::= { fiberCheckStatPortEntry 2 }

    fiberCheckStatSN OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The serial number of fiber module."
        ::= { fiberCheckStatPortEntry 3 }

    fiberCheckStatWaveLength OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The wavelength of fiber module."
        ::= { fiberCheckStatPortEntry 4 }

    fiberCheckStatTemperatureC OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature(Celsius) of fiber module."
        ::= { fiberCheckStatPortEntry 5 }

    fiberCheckStatTemperatureF OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature(Fahrenheit) of fiber module."
        ::= { fiberCheckStatPortEntry 6 }

    fiberCheckStatVoltage OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The voltage of fiber module."
        ::= { fiberCheckStatPortEntry 7 }

    fiberCheckStatTxPower OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The tx power of fiber module."
        ::= { fiberCheckStatPortEntry 8 }

    fiberCheckStatRxPower OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The rx power of fiber module."
        ::= { fiberCheckStatPortEntry 9 }

    fiberCheckStatTemperatureLimitC OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature(Celsius) warning limit of fiber module."
        ::= { fiberCheckStatPortEntry 10 }

    fiberCheckStatTemperatureLimitF OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature(Fahrenheit) warning limit of fiber module."
        ::= { fiberCheckStatPortEntry 11 }

    fiberCheckStatTxPowerLimit OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The tx power warning limit of fiber module."
        ::= { fiberCheckStatPortEntry 12 }

    fiberCheckStatRxPowerLimit OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The rx power warning limit of fiber module."
        ::= { fiberCheckStatPortEntry 13 }

-- -------------------------------------------------------------
-- Notification group
-- -------------------------------------------------------------

    fiberCheckNotifyFiberCheckWarning NOTIFICATION-TYPE
        OBJECTS     { fiberCheckStatPortIndex }
        STATUS      current
        DESCRIPTION
            "Notification indicates fiber check warning."
        ::= { fiberCheckNotification 1 }
END